What is the maintenance work of the swine fever detection centrifuge?
Proper maintenance and upkeep of equipment can not only ensure its correct operation, but also increase its service life. Some users are not unwilling to maintain their equipment, but do not know how to proceed. So, what are the maintenance tasks for African swine fever detection centrifuges?
1. The mesh size of the filter cloth should be determined according to the size of the solid particles of the separated material, otherwise it will affect the separation effect.
2. Special personnel are required to operate, and the capacity must not exceed the rated amount.
3. It is strictly prohibited to operate the machine at excessive speed to avoid affecting its service life.
4. In addition, when installing the filter cloth, the sealing ring of the filter cloth should be embedded in the sealing groove of the drum to prevent materials from running in.
5. To ensure the normal operation of the centrifuge, please refuel and maintain the rotating parts every 6 months.
6. Before operating the centrifuge, the power should be cut off and the centrifuge brake should be released first. You can manually try rotating the drum to see if there is any biting.
7. Check for looseness and abnormal conditions in other parts.
8. Turn on the power and drive clockwise to start (usually taking about 40-60 seconds from a stationary state to normal operation).
9. At the same time, check the lubrication condition of the bearings and whether there is any wear or tear; Check if there is any wear and tear on the components in the braking device, and replace them if necessary; Check for oil leakage in the bearing cover.
10. After using the machine, it should be cleaned and kept tidy.
11. Do not separate non corrosion resistant centrifuges from highly corrosive materials; In addition, strictly follow the equipment requirements and regulations for operation. Non explosion proof centrifuges must not be used in flammable or explosive environments.
12. Usually, each device needs to run empty for about 3 hours after arriving at the factory, and can only work if there are no abnormal conditions.
13. Materials should be placed as evenly as possible.
14. After the machine is started, if there are any abnormal situations, it should be stopped for inspection and dismantled, cleaned, and repaired if necessary.
15. The African swine fever detection centrifuge operates at high speed, so do not touch its drum with your body to avoid accidents.